Volumetric evaluation of various obturation techniques in primary teeth using cone beam computed tomography – An in vitro study: NB Nagaveni, Sneha Yadav, P Poornima, KP Bharath, Mebin George Mathew, PG Naveen Kumar
Journal of Indian Society of Pedodontics and Preventive Dentistry 2017 35(3):244-248
Aim: The aim of this study was to compare and evaluate the efficiency of five different obturation methods in delivering the filling material into the canals of primary teeth using cone beam computerized tomography (CBCT) scan. Method: A total of fifty prepared canals of primary teeth which further divided into five groups with ten canals in each group were obturated with zinc oxide-eugenol cement using five different obturation methods such as endodontic plugger, lentulo spiral (handheld), lentulo spiral mounted on slow speed handpiece, local anesthetic syringe, and tuberculin syringe. Using CBCT scan, the pre- and post-obturation volume and the percentage of obturated volume (POV) were calculated for each group. The results obtained were statistically analyzed using one-way analysis of variance and Tukey's post hoc test. Results: Following CBCT scan, the method obturated with lentulo spiral mounted to handpiece showed the highest POV value followed by the method of lentulo spiral mounted to handpiece, hand plugger, and tuberculin syringe. Local anesthetic syringe gave the least POV (P < 0.05). Conclusion: Lentulo spiral mounted to handpiece showed the best technique of obturation using CBCT evaluation among the five groups evaluated in primary teeth. However, more studies are highly essential to prove it a boon for estimating obturation quality in primary teeth.
http://ift.tt/2wd2Aaw
Ιατρική : Τα αισθητικά συστήματα της όρασης,ακοής,αφής,γεύσης και όσφρησης.
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Background Mindfulness based stress reduction (MBSR) is increasingly being used to improve outcomes such as stress and depression...
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, Medicine by Alexandros G. Sfakianakis,...
-
Objective: We compare the effect of daily versus weekly levothyroxine (LT4) replacement on thyroid function test (TFT) in hypothyroid patie...
-
Publication date: May 2017 Source: Neuroimaging Clinics of North America, Volume 27, Issue 2 http://ift.tt/2pfyuQ5 http://ift.tt/2...
-
Evaluation of Noise Exposure Secondary to Wind Noise in Cyclists. : Evaluation of Noise Exposure Secondary to Wind Noise in Cyclist...
-
Immunotherapy for thoracic malignancies : Abstract Purpose Historically, thoracic malignancies, such as non-small cell lung cancer and...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου