Accuracy of magnetic resonance imaging for measuring maturing cartilage: A phantom study: OBJECTIVES: To evaluate the accuracy of magnetic resonance imaging measurements of cartilage tissue-mimicking phantoms and to determine a combination of magnetic resonance imaging parameters to optimize accuracy while minimizing scan time. METHOD: Edge dimensions from 4 rectangular agar phantoms ranging from 10.5 to 14.5 mm in length and 1.25 to 5.5 mm in width were independently measured by two readers using a steel ruler. Coronal T1 spin echo (T1 SE), fast spoiled gradient-recalled echo (FSPGR) and multiplanar gradient-recalled echo (GRE MPGR) sequences were used to obtain phantom images on a 1.5-T scanner. RESULTS: Inter- and intra-reader reliability were high for both direct measurements and for magnetic resonance imaging measurements of phantoms. Statistically significant differences were noted between the mean direct measurements and the mean magnetic resonance imaging measurements for phantom 1 when using a GRE MPGR sequence (512x512 pixels, 1.5-mm slice thickness, 5:49 min scan time), while borderline differences were noted for T1 SE sequences with the following parameters: 320x320 pixels, 1.5-mm slice thickness, 6:11 min scan time; 320x320 pixels, 4-mm slice thickness, 6:11 min scan time; and 512x512 pixels, 1.5-mm slice thickness, 9:48 min scan time. Borderline differences were also noted when using a FSPGR sequence with 512x512 pixels, a 1.5-mm slice thickness and a 3:36 min scan time. CONCLUSIONS: FSPGR sequences, regardless of the magnetic resonance imaging parameter combination used, provided accurate measurements. The GRE MPGR sequence using 512x512 pixels, a 1.5-mm slice thickness and a 5:49 min scan time and, to a lesser degree, all tested T1 SE sequences produced suboptimal accuracy when measuring the widest phantom.
http://ift.tt/2agzGAk
Ιατρική : Τα αισθητικά συστήματα της όρασης,ακοής,αφής,γεύσης και όσφρησης.
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Evaluating polymyxin B-based combinations against carbapenem-resistant Escherichia coli in time-kill studies and in a hollow-fiber infection...
-
Mickey mouse sign Mickey Mouse sign From Wikipedia, the free encyclopedia Jump to navigation Jump to search Mickey Mouse sign is a medical ...
-
Abstract This paper proposes a novel system to protect the fingerprint database based on compressed binary fingerprint images. In this sys...
-
Abstract: Facial duplication, in whole or in part, is a very rare malformation. It may be symmetrical or asymmetric. Those cases that have b...
-
Publication date: Available online 1 April 2017 Source: International Journal of Oral and Maxillofacial Surgery Author(s): I. Astramskaitė...
-
Abstract: The purpose of this study was to histologically evaluate the effects on bone healing of nigella sativa seed extract applied on cal...
-
http://ift.tt/2pBe1J0 http://ift.tt/2pPXS3k
-
Abstract: Unicoronal craniosynostosis predisposes to ophthalmologic abnormalities such as strabismus, astigmatism, and amblyopia. The author...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου