Accuracy of magnetic resonance imaging for measuring maturing cartilage: A phantom study: OBJECTIVES: To evaluate the accuracy of magnetic resonance imaging measurements of cartilage tissue-mimicking phantoms and to determine a combination of magnetic resonance imaging parameters to optimize accuracy while minimizing scan time. METHOD: Edge dimensions from 4 rectangular agar phantoms ranging from 10.5 to 14.5 mm in length and 1.25 to 5.5 mm in width were independently measured by two readers using a steel ruler. Coronal T1 spin echo (T1 SE), fast spoiled gradient-recalled echo (FSPGR) and multiplanar gradient-recalled echo (GRE MPGR) sequences were used to obtain phantom images on a 1.5-T scanner. RESULTS: Inter- and intra-reader reliability were high for both direct measurements and for magnetic resonance imaging measurements of phantoms. Statistically significant differences were noted between the mean direct measurements and the mean magnetic resonance imaging measurements for phantom 1 when using a GRE MPGR sequence (512x512 pixels, 1.5-mm slice thickness, 5:49 min scan time), while borderline differences were noted for T1 SE sequences with the following parameters: 320x320 pixels, 1.5-mm slice thickness, 6:11 min scan time; 320x320 pixels, 4-mm slice thickness, 6:11 min scan time; and 512x512 pixels, 1.5-mm slice thickness, 9:48 min scan time. Borderline differences were also noted when using a FSPGR sequence with 512x512 pixels, a 1.5-mm slice thickness and a 3:36 min scan time. CONCLUSIONS: FSPGR sequences, regardless of the magnetic resonance imaging parameter combination used, provided accurate measurements. The GRE MPGR sequence using 512x512 pixels, a 1.5-mm slice thickness and a 5:49 min scan time and, to a lesser degree, all tested T1 SE sequences produced suboptimal accuracy when measuring the widest phantom.
http://ift.tt/2agzGAk
Ιατρική : Τα αισθητικά συστήματα της όρασης,ακοής,αφής,γεύσης και όσφρησης.
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Your subscribed feeds are not being updated automatically because this setting is turned off. Turn on automatic feed updates You'...
-
Background/Purpose Facial lipoatrophy in HIV patients, secondary to antiretroviral therapy (ART) with thymidine analogs, has been related ...
-
Related Articles BioBits™ Explorer: A modular synthetic biology education kit. Sci Adv. 2018 Aug;4(8):eaat5105 Authors: Huang A, Ngu...
-
Preintravenous injection of parecoxib, combined with transversus abdominis plane block in strategy of enhanced recovery after radical resect...
-
Abstract Malakoplakia is a rare inflammatory condition that typically occurs in the urinary tract. The cutaneous form is less prevalent, an...
-
Related Articles Oleogustus: The Unique Taste of Fat. Chem Senses. 2015 Sep;40(7):507-16 Authors: Running CA, Craig BA, Mattes RD A...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου