Publication date: July 2016
Source:American Journal of Orthodontics and Dentofacial Orthopedics, Volume 150, Issue 1
Author(s): Elizabeth M. Jones, Melissa Papio, Boon Ching Tee, Frank M. Beck, Henry W. Fields, Zongyang Sun
IntroductionPrevious studies have indicated that orthodontic-grade cone-beam computed tomography (CBCT) images are limited when displaying small defects at the mandibular condyles for diagnosis. In this study, we investigated whether this limitation was inherent to CBCT by comparing CBCT with multislice computed tomography (CT), and whether image segmentation and color mapping could overcome this limitation.MethodsNine fresh pig heads (18 condyles, 36 medial and lateral condylar regions) were used. Small osseous defects (diameter and depth, 1.5 mm) were created at the medial and lateral regions of the condyles shown by gutta percha markers. After the overlying soft tissues were restored, the pig heads underwent orthodontic-grade CBCT scans (0.4-mm voxel size; i-CAT; Imaging Sciences International, Hatfield, Pa) and medical-grade CT scans (0.625-mm voxel size; LightSpeed; GE, Little Chalfont, Buckinghamshire, United Kingdom). Subsequently, 2 calibrated and blinded raters diagnosed the defect numbers in each condylar region from CBCT and CT images using Dolphin 3D software (Patterson Supply, St Paul, Minn) without image segmentation, and then 1 week later with the proprietary image segmentation and color mapping tools of Dolphin 3D. Condylar polyvinyl siloxane impressions were collected and evaluated by the same raters to obtain physical diagnoses. Rediagnoses were made on randomly selected subsamples to assess reliability. Using the physical diagnoses as references, the accuracy of imaging diagnosis was assessed and statistically compared among the varied imaging and analysis methods.ResultsImage diagnoses of all imaging and analysis methods showed good or excellent intrarater and interrater reliability values, except for those of the segmented CBCT images, which were substantially lower. The numbers of overdiagnoses and underdiagnoses per condylar region were not significantly different among the varied imaging and analysis methods (Wilcoxon tests, P >0.05), but classification functions demonstrated substantially lower sensitivity and accuracy with CBCT than with CT. Logistic regression also showed that CT had a significantly higher probability (odds ratio, 2.4) than CBCT in reaching the correct diagnosis, whereas use of the image segmentation and color mapping tool proprietary to Dolphin 3D did not improve the diagnostic accuracy from CBCT images.ConclusionsEven at a lower voxel size than medical CT images, orthodontic-grade CBCT images of mandibular condyles may be inherently less reliable and less accurate for the diagnosis of small condylar defects.
http://ift.tt/296cWwO
http://ift.tt/298tepk
Ιατρική : Τα αισθητικά συστήματα της όρασης,ακοής,αφής,γεύσης και όσφρησης.
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract The silver palladium bimetallic core-shell structure nanoparticles (Ag@Pd NPs) were synthesized by a thin Pd shell slowly generat...
-
Publication date: May 2017 Source: The Kaohsiung Journal of Medical Sciences, Volume 33, Issue 5 http://ift.tt/2pFwvby http://ift....
-
Background: Clinically used antibiotics act through one of these four mechanisms: cell wall biosynthesis inhibition, inhibition of protein b...
-
Abstract Objective When multiple visible teeth are prepared, the prolonged treatment time may lead to patients needing a break that requ...
-
Transplanters drive CARs to the clinic by brewing ICE-T: the Moffitt roadmap : Abstract Recent single institution clinical trial success...
-
in a cancer patient with elevated anti-striated muscle antibody : Abstract Background Immune checkpoint inhibitors have revolutionize...
-
The goal of this study is to evaluate the impact of chronic rhinosinusitis with nasal polyps (CRSwNP) on sleep pattern and sleep quality bef...
-
AbstractBackground Cardiac sympathetic denervation (CSD) has been shown to reduce the burden of implantable cardioverter-defibrillator (ICD...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου